Sold out
Inverter GROWATT MOD 10KTL3-X, 10kW, 3-phase, 2 MPPT
1,189.10€
Inverter GROWATT MOD 10KTL3-X, 10kW, 3-phase, 2 MPPT
Out of stock
Description
Inverter GROWATT MOD 10KTL3-X, 10kW, 3-phase, 2 MPPT
Specifications
Input (DC) | |
Recommended max. PV input power | 15000 W |
Max. PV input voltage | 1100 V |
Start-up input voltage | 160 V |
Rated input voltage | 580 V |
MPP voltage range | 140 V – 1000 V |
No. of independent MPP inputs | 2 |
No. of PV strings per MPP | 1 |
Max. input current per MPP tracker | 13 A |
Max. short-circuit current per MPP tracker | 16 A |
Output (AC) | |
Rated AC output power | 10000 W |
Max. AC output apparent power | 11000 VA |
Rated AC voltage(range) | 220/380 V, 230/400 V (340-440 V) |
Max. output current | 16.7 A |
AC grid frequency | 50 Hz / 60 H |
AC grid frequency range | 45 – 55 Hz / 55 – 65 Hz |
Harmonic (THD) | < 3 % (at rated power) |
Adjustable power factor | 0.8 leading – 0.8 lagging |
AC grid connection type | 3 W + N + PE |
Efficiency | |
Max. efficiency | 98.6% |
European efficiency | 98.1% |
MPPT efficiency | 99.9% |
Protection devices | |
Grid monitoring | yes |
DC reverse polarity protection | yes |
AC short-circuit protection | yes |
Insulation resistance monitoring | yes |
Surge Protection | DC Type II / AC Type II |
Ground fault monitoring | yes |
DC switch | yes |
String fault monitoring | yes |
Arc fault circuit interrupter (AFCI) | optional |
Anti-islanding protection | yes |
Residual-current monitoring unit | yes |
General Data | |
Dimensions(W*H*D) | 425*387*178 m |
Weight | 14 kg |
Topology | Transformerless |
Degree of protection | IP66 |
Night power consumption | < 1 W |
Operating ambient temperature range | -25 °C to +60 °C |
Allowable relative humidity range (non-condensing) | 0% – 100% |
Cooling method | Natural convection |
Max. operating altitude | 4000 m |
Display | OLED + LED / WiFi + app |
Interfaces | RS-485 / USB |
Optional interfaces | Wi-Fi / GPRS / RF / LAN |
AC connection type | Connector |
Certification | CE, VDE0126, Greece, EN50549, C10/C11, UTE C 15-712, IEC62116, IEC61727, IEC 60068, IEC 61683, CEI0-21, N4105, TOR Erzeuger G98/G99, G100, AS4777, UNE217001, UNE206007, PO12.2 |
Warranty: The warranty of the voltage converter (inverter) is valid from the day when we (the seller) is provided with the serial number of the inverter, the purchase invoice, a certified electrician’s certificate about the installed:1) Lightning protection and overvoltage limiter (on the input side)2) Lightning protection (between solar panels and inverter)3) DC voltage switch between panels and inverter4) Dedicate grounding for solar panels separated from grounding of the house
The 10-year (120-month) manufacturer’s warranty begins from the day of purchase, but comes into effect only after submission of these documents.Note: Lightning strike is not a valid warranty claim, it is classified as insurance claim.
Tarneinfo
Transport information
Goods are generally dispatched from 3 warehouses.
Warehouses:
Tartu warehouse - delivery time 1-3 working days
Central warehouse 1 - delivery time 3-6 working days
- Central warehouse 2 - delivery time 5-9 working days
In the case of special orders, subsequent or partial deliveries, the delivery time will be specified by Customer Service.